This project is taking longer than anticipated even though it was supposed to be something simple. I will publish a schematic of the complete circuit in the near future (this year) but in the meantime there is still the slow process of troubleshooting. Safety considerations: the complete circuit is not isolated from mains so testing is pretty critical. I have been feeding 3.6V to test the low-voltage part but in the end it will have to be hooked up to 220V the boiler / water heater can only take a limited amount of pressure. If the thermistor is not properly calibrated in software there is the risk of a scalding hot water explosion With that being said there is some small but steady progress being done. The MSP430 has a some strange power requirements that are not properly documented. The VCC supply needs to rise with >1V/ms otherwise it gets into an undefined state. That undefined state might also mean that some GPIOs are high, causing catastrophical failure. C...